Sewer area (Water Overlay): Difference between revisions

From Tygron Preview Support Wiki
Jump to navigation Jump to search
m (Frank@tygron.nl moved page Sewer Area (Water Overlay) to Sewer area (Water Overlay) without leaving a redirect)
No edit summary
Line 11: Line 11:
|unit=m
|unit=m
|description=The maximum water height the sewer can store. This value, multiplied by the grid cell size and the amount of grid cells marked as sewered, forms the total amount of water this sewer can store.
|description=The maximum water height the sewer can store. This value, multiplied by the grid cell size and the amount of grid cells marked as sewered, forms the total amount of water this sewer can store.
|defaultvalue=n/a
|defaultvalue=0
|icon=[[File:waterwizard_icon_sewer_storage.png]]
|icon=[[File:waterwizard_icon_sewer_storage.png]]
|attribute2=[[Sewer_pump_speed_(Water_Overlay)|SEWER_PUMP_SPEED]]
|attribute2=[[Sewer_pump_speed_(Water_Overlay)|SEWER_PUMP_SPEED]]
Line 19: Line 19:
|icon2=[[File:waterwizard_icon_sewer_pump_speed.png]]
|icon2=[[File:waterwizard_icon_sewer_pump_speed.png]]
}}
}}
 
==Notes==
Sewers do not have default storage amount, but when generating them automatically in the {{inlink|lcase=1|Configuration wizard}}, suggested values are 0,007m for older sewers and 0,04 for newer sewers.
* Sewers do not have default storage amount, but when generating them automatically in the {{inlink|lcase=1|Configuration wizard}}, suggested values are 0,007m for older sewers and 0,04 for newer sewers.
{{WaterOverlay object nav}}
{{WaterOverlay object nav}}

Revision as of 12:23, 4 April 2019

A sewer area is part of the definition of a system of sewers in the specified area. Sewer storage is present in the hydrological model wherever the sewer area intersects with a sewered construction.

Similar to water level areas, sewer areas only define a sewer storage amount in grid cells that are marked as sewered. A grid cell is marked as sewered, if:

  1. It is covered by a construction with a SEWERED attribute > 0.
  2. It is covered by a sewer area with a SEWER_STORAGE attribute > 0.

A sewer area can also pump stored sewer water to an external area outside the project. However, water that has been pumped out will remain in the external area and cannot be pumped back. By default sewers do not pump water to external areas.

Template:Overlay attribute

Notes

  • Sewers do not have default storage amount, but when generating them automatically in the configuration wizard, suggested values are 0,007m for older sewers and 0,04 for newer sewers.

Template:WaterOverlay object nav