Revision as of 14:44, 17 July 2020

Underground seepage (from (or to) outside the project area) is calculated per cell.

The seepage is calculated using the following formula:

Δs=hd(t)hx,ycΔt246060

The external seepage head is variable over time by the introduction of hv,t

hd(t)=hc+hv,t(t)

Finally, calculate the actual amount of water seeping into (or out of) the ground from the bottom.

Δw=Δsws

Where:

  • Δs = The underground seepage which takes place, in meters.
  • Δt = Computational timestep in seconds.
  • hx,y = Ground water head in the grid cell.
  • hd,t = ground water level (or head) of the external zone causing the seepage at time t, in meters
  • hc = constant ground water level (or head) of the external zone causing the seepage, in meters
  • hv,t = additional variation of seepage head over time
  • c = resistance of the separating layer in days
  • ws = water storage fraction of the soil

See also

Template:WaterOverlay nav