Oxidation formula (Subsidence Overlay): Difference between revisions

From Tygron Preview Support Wiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 7: Line 7:
* <math>S_O</math> is the subsidence due to oxidation.
* <math>S_O</math> is the subsidence due to oxidation.
* <math>d_{gw,y}</math> is the [[Ground water depth formula (Subsidence Overlay)|calculated ground water depth]] for year y.
* <math>d_{gw,y}</math> is the [[Ground water depth formula (Subsidence Overlay)|calculated ground water depth]] for year y.
* <math>a_{y}</math> is the [[calculated a parameter value]] for the current year <math>y</math>.
* <math>a_{y}</math> is the [[Parameter_a_recalculation_formula_(Subsidence_Overlay)|calculated a parameter value]] for the current year <math>y</math>.
* <math>d_{ct}</math> is the clay thickness of the terrain, defined by [[Clay thickness (Subsidence Overlay)|CLAY_THICKNESS]]
* <math>d_{ct}</math> is the clay thickness of the terrain, defined by [[Clay thickness (Subsidence Overlay)|CLAY_THICKNESS]]
* <math>b</math> is the b parameter value, defined by [[Parameter b (Subsidence Overlay)|PARAMETER B]]
* <math>b</math> is the b parameter value, defined by [[Parameter b (Subsidence Overlay)|PARAMETER B]]

Revision as of 09:39, 9 February 2021

The amount of subsidence due to oxidation is calculated by the following formula:

where

  • is the subsidence due to oxidation.
  • is the calculated ground water depth for year y.
  • is the calculated a parameter value for the current year .
  • is the clay thickness of the terrain, defined by CLAY_THICKNESS
  • is the b parameter value, defined by PARAMETER B
  • is the c parameter value, defined by PARAMETER C

This formula was provided by experts, who have derived this formula empirically.