Subsidence formula (Subsidence Overlay)

From Tygron Preview Support Wiki
Revision as of 08:02, 9 October 2025 by Maxim@tygron.com (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
This functionality is deprecated and will be removed in the future.

The total subsidence for year y is calculated as:

Sy,max=dtl,cpcSy1

SO,y=min(Sy,max,SO,y)

Sy,max=Sy,maxSO,y

SC,y=min(Sy,max,SC,y)

Sy=SO,y+SC,y

where

pc is the peat fraction of the respective grid cell c.
dtl,c is the top layer thickness of the respective grid cell c.
Sy,max is the maximum possible subsidence in year y.
Sy is the total subsidence in year y
SO,y is the subsidence due to oxidation in year y.
SC,y is the subsidence due to compactions in year y.