Overflow from the sewer is calculated for the entirety of the sewer, and the single attached sewer overflow.

The sewer base height is located at the height indicated by the sewer overflow:

Bs = Bo

The water level at the sewer is calculated based on that height:

ws = hs + Ba

The sewer overflow threshold height Ho within the sewer is calculated as:

Ho = Hs * To

Water only flows out of the sewer if:

hs > Ho and
hs + Bs > wo

The amount that can overflow relies on both the water level at the sewer overflow itself as well as the sewer overflow threshold and the stored sewer water:

Δh = min ( hs - Ho , ws - wo)

The flow is then calculated with the SEWER_OVERFLOW_SPEED attribute of the sewer overflow and the maximum speed with which water can flow through the sewer overflow:

Δw = min( Δh, Δt * qo / As)

The amount of water added to the exit cell(s) of the sewer overflow:

Qt = Δw * As

where:

  • hs = The sewer water height.
  • Hs = The SEWER_STORAGE attribute of the sewer area, the maximum water height allowed in the sewer.
  • Δh = The amount of water that can flow out of sewer based on the threshold and the water levels inside and outside the sewer.
  • Δw = Water level change in the sewer, due to sewer overflow taking place.
  • Δt = Computational timestep.
  • As = The surface area of the sewer.

Notes

  • The sewer's surface area is computed as the amount of sewered grid cells times the size of a grid cell.
  • The sewer's height relative to datum is not defined in the sewer itself. It is relative to the sewer overflow and determined by the SEWER_OVERFLOW attribute of the overflow.