The amount of subsidence due to oxidation is calculated by the following formula:

where

is the subsidence due to oxidation.
is the calculated ground water depth for year y.
is the calculated a parameter value for the current year .
is the clay thickness of the terrain, defined by CLAY_THICKNESS
is the b parameter value, defined by the model attribute B
is the c parameter value, defined by the model attribute C

This formula was provided by experts, who have derived this formula empirically.