Compaction formula (Subsidence Overlay)

From Tygron Support wiki
Revision as of 16:47, 8 February 2021 by Frank@tygron.nl (talk | contribs)
Jump to navigation Jump to search

The amount of subsidence due to compaction is calculated by the following formula:

where

  • is the peat fraction of the cell at coordinate (x,y)
  • is the top layer thickness of the cell at coordinate (x,y)
  • The height increase as a result of the actions taken during a session, such as the creation of levees.
  • is the number of days in a year times the current year being calculated.
  • is the first regression constant (-0.015853041) for the effect of the peat fraction and time in days.
  • is the second regression constant (0.02348519) for the effect of the peat fraction.
  • is the first regression constant (-0.006617643) for the top layer thickness and time in days.
  • is the second regression constant (0.010061616) for the top layer thickness.
  • is a regression constant (-0.200468677) for the change in surface height, for example caused by added materials.

This formula is based on provided expert data in the form of a reference table, indicating the amount of subsidence based on the parameters used in the formula above. The formula's results conform to the reference table to within an average of a tenth of the margin of error of the original table.