When working with the [[Underground model (Water Overlay)|full groundwater model]] of the [[Water Overlay]], underground seepage may present a significant factor in the underground water balance. However, especially over longer times, the effects of external seepage can vary. For these situations, it is possible to introduce a time-dependant [[seepage fluctuation (Water Overlay)|variation to the seepage]].
When working with the [[Underground model (Water Overlay)|full groundwater model]] of the [[Water Overlay]], underground seepage may present a significant factor in the underground water balance. However, especially over longer times, the effects of external seepage can vary. For these situations, it is possible to introduce a time-dependant [[seepage fluctuation (Water Overlay)|variation to the seepage]].


For seepage to be functional, two [[seepage GeoTiffs (Water Overlay)|Seepage GeoTiff]]s are required and must be prepared beforehand. Additionally, a [[csv]] with a {{time sequence start}} [[time sequence (Water Overlay)|time sequence]] for the [[Seepage fluctuation (Water Overlay)|seepage fluctuation]] should be prepared.
For seepage to be functional, the following should be prepared beforehand:
* Two [[seepage GeoTiffs (Water Overlay)|Seepage GeoTiff]]s, one for pressure and one for resistances.
* A [[csv]] with a {{time sequence start}} [[time sequence (Water Overlay)|time sequence]] for the [[Seepage fluctuation (Water Overlay)|seepage fluctuation]].


{{editor location|Overlay wizard|Water Overlay|Seepage}}
{{editor location|Overlay wizard|Water Overlay|Seepage}}

Revision as of 08:48, 27 April 2021

When working with the full groundwater model of the Water Overlay, underground seepage may present a significant factor in the underground water balance. However, especially over longer times, the effects of external seepage can vary. For these situations, it is possible to introduce a time-dependant variation to the seepage.

For seepage to be functional, the following should be prepared beforehand:

Editor → Current Situation (Ribbon tab) → Overlays (Ribbon bar) → Water Overlay (Left panel) → Configuration Wizard (Right panel) → Seepage
How to configure variable seepage:
  1. Open the Water Overlay Wizard, and proceed to the seepage step.
  2. Opt to configure seepage.
  3. For the pressure geotiff, import your GeoTiff with seepage pressure values.
  4. Ensure the uploaded geotiff is selected in the dropdown.
  5. For the resistance geotiff, import your GeoTiff with seepage resistance values.
  6. Ensure the uploaded geotiff is selected in the dropdown.
  7. Set the seepage factor to "dynamic", and opt to select a csv.
  8. Import the prepared csv.
  9. Close the import window.
  10. Close the configuration wizard, and recalculate the Overlay.