How to configure constant bottom boundary flow (Water Overlay): Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
When working with the [[Underground model (Water Overlay)|full groundwater model]] of the [[Water Overlay]], underground seepage may present a significant factor in the underground water balance. For these situations, underground seepage can be configured. | When working with the [[Underground model (Water Overlay)|full groundwater model]] of the [[Water Overlay]], underground seepage may present a significant factor in the underground water balance. For these situations, underground seepage can be configured. | ||
For seepage to be functional, | For seepage to be functional, the [[seepage p prequel (Water Overlay)|Seepage p prequel]] and [[seepage c prequel (Water Overlay)|Seepage c prequel]] are required and must be prepared beforehand. | ||
{{editor location|Overlay wizard|Water Overlay|Seepage}} | {{editor location|Overlay wizard|Water Overlay|Seepage}} | ||
Line 7: | Line 7: | ||
{{howto|title=configure constant seepage | {{howto|title=configure constant seepage | ||
| Open the [[Water Overlay Wizard]], and proceed to the seepage step. | | Open the [[Water Overlay Wizard]], and proceed to the seepage step. | ||
| Opt to select seepage | | Opt to select seepage Grid Overlays and define the seepage factor. | ||
| For the pressure | | For the pressure Grid, import your [[seepage p prequel (Water Overlay)|GeoTIFF Overlay with seepage pressure values]]. | ||
| Ensure the uploaded | | Ensure the uploaded GeoTiff Overlay is selected in the dropdown. | ||
| For the resistance | | For the resistance Grid, import your [[seepage c prequel (Water Overlay)|GeoTIFF Overlay with seepage resistance values]]. | ||
| Ensure the uploaded GeoTIFF is selected in the dropdown. | | Ensure the uploaded GeoTIFF Overlay is selected in the dropdown. | ||
| Close the configuration wizard, and [[recalculate|recalculate the Overlay]]. | | Close the configuration wizard, and [[recalculate|recalculate the Overlay]]. | ||
}} | }} |
Revision as of 12:55, 10 February 2022
When working with the full groundwater model of the Water Overlay, underground seepage may present a significant factor in the underground water balance. For these situations, underground seepage can be configured.
For seepage to be functional, the Seepage p prequel and Seepage c prequel are required and must be prepared beforehand.
Editor → Current Situation (Ribbon tab) → Overlays (Ribbon bar) → Water Overlay (Left panel) → Configuration Wizard (Right panel) → Seepage
How to configure constant seepage:
- Open the Water Overlay Wizard, and proceed to the seepage step.
- Opt to select seepage Grid Overlays and define the seepage factor.
- For the pressure Grid, import your GeoTIFF Overlay with seepage pressure values.
- Ensure the uploaded GeoTiff Overlay is selected in the dropdown.
- For the resistance Grid, import your GeoTIFF Overlay with seepage resistance values.
- Ensure the uploaded GeoTIFF Overlay is selected in the dropdown.
- Close the configuration wizard, and recalculate the Overlay.