Waterway level change benchmark (Water Module): Difference between revisions

From Tygron Support wiki
Jump to navigation Jump to search
Line 30: Line 30:


===Setup===
===Setup===
The test setup uses the same parameters used in the research results published in <ref name="Ernst"/>
The grid chosen is 51 by 7. The ground water table comparisons will be conducted in the x-direction.
The grid chosen is 51 by 7. The ground water table comparisons will be conducted in the x-direction.



Revision as of 10:48, 11 December 2020

Initially, the ground water table is the same as the water level in the waterway. Suddenly the level in the waterway rises with h0 meters. This causes water to infiltrate into the ground, raising the ground water table.

Situation of the waterway level change benchmark for groundwater

Formulas

When the water level in the water way changes, the water table level will also change over time. The relation between water level in the waterway and the ground water table at distance x from the water way is described by the following formulas: In case teh water level is raised, the following formula should hold:

In case the water level is lowered, the following formula should hold:

The formula erf is the complementary error function.

where:

: change in freatic groundwater table (m)
: change in water level in the waterway(m)
: distance to the water way (m)
: time since the water level change
: transmissivity of the aquifer (m2 / day)
: freatic water storage fraction.

The expected values are visualized in this graph

Setup

The test setup uses the same parameters used in the research results published in [1] The grid chosen is 51 by 7. The ground water table comparisons will be conducted in the x-direction.

The terrain height is set up as followed:



On x is ?, from y 1 to 6, a unique Inlet is placed, each with:

UPPER_THRESHOLD set to X.
LOWER_THRESHOLD set to X.
Inlet Q set to 0, such that is unlimited.

This ensures that the water level is instantly raised to level X and that it remains at X at all times.

The ground is setup with: Water storage fraction set to 0.25.

An aquifer is added for the region as well, initialized with the Aquifer KD set to 700 m2/day.

A ground water overlay is used for the simulation, with a simulation time T configured using the Weather's rain M parameter, set to [T, 0.0], resulting in a simulation of T seconds without rain. Note that T has to be converted to days to be used in the formula's described above.

Results

  1. Cite error: Invalid <ref> tag; no text was provided for refs named Ernst

Cite error: <ref> tag with name "Ernst58" defined in <references> is not used in prior text.
Cite error: <ref> tag with name "Marsily" defined in <references> is not used in prior text.