===Test case | ===Test case 4C=== | ||
In this testcase, the amount of rainfall and the infiltration capacity are equal to [[#testcase 4B|testcase 4B]]. The porosity of the soil is now set to 0.25. The impenetrable layer is strictly horizontal and 10 meters below the lowest surface height. The groundwatertable at t=0 is horizontal, 50 cm below the height of the weir. The initial surface water level is equal to the initial groundwatertable. The hydraulic condictivity is 5x10<sup>-5</sup> for water infiltration from the surface to the underground. The simulation time is equal to testcase 4B. |
Revision as of 09:55, 9 April 2019
Test case 1
Test case 2
Test case 3
Test case 4
Test case 4a
Test case 4b
Test case 4C
In this testcase, the amount of rainfall and the infiltration capacity are equal to testcase 4B. The porosity of the soil is now set to 0.25. The impenetrable layer is strictly horizontal and 10 meters below the lowest surface height. The groundwatertable at t=0 is horizontal, 50 cm below the height of the weir. The initial surface water level is equal to the initial groundwatertable. The hydraulic condictivity is 5x10-5 for water infiltration from the surface to the underground. The simulation time is equal to testcase 4B.