Water manning (Water Overlay): Difference between revisions

From Tygron Preview Support Wiki
Jump to navigation Jump to search
mNo edit summary
No edit summary
 
(18 intermediate revisions by 5 users not shown)
Line 1: Line 1:
{{Overlay attribute
[[File:Manning_value.png|thumb|200px|right|The default function values for a number of buildings. The user can easily change these values.]]
|attribute=WATER_MANNING
{{Building attributes
|unit=s/(m<sup>1/3</sup>)
| <onlyinclude>
|functionvalue=Manning Value
{{Building attributes|type=row|group=Water Overlay
|description=The Gauckler–Manning coefficient of the construction.
|attribute=WATER_MANNING
|icon=[[File:waterwizard_icon_manning.png]]
|unit=s/(m<sup>1/3</sup>)
|functionvalue=Manning Value
|description=The Gauckler–Manning coefficient of the building.
|icon=waterwizard_icon_manning.png
|range=0.01 to 0.255
}} </onlyinclude>
}}
}}
===Manning value (construction)===
[[Construction]]s have an inherent "roughness", which influences how fast water can flow across the surface. This is known as the Manning coefficient or Manning value.


===Notes===
[[Building]]s have an inherent "roughness", affecting the flow of water across their surface, which is expressed by the Gauckler–Manning coefficient or, in short, Manning's value (''n'').
* If no construction is present in a location, the [[Terrain water manning (Water Overlay)|WATER_MANNING]] value of the surface terrain in that location is used instead.
{{clear}}
 
{{article end
==How-to's==
|notes=
* [[How-to add and remove an attribute|Add and remove an attribute]]
* The [[Manning prequel (Water Overlay)|manning value]] can alternatively be provided as a [[prequel]].
 
* The default function values are derived from online accessible databases<ref name="WikiEngineer"/> and are readily adjustable by the user.
==See also==
* If no Buildings are present on a [[Terrain]], the [[Terrain water manning (Water Overlay)|WATER_MANNING]] value of the surface terrain is used.
* [[Surface flow formula (Water Overlay)|Surface flow formula]]
|seealso=
* [[Surface model (Water Overlay)|Surface model]]
* [[Surface flow formula (Water Overlay)]]
* [[Surface model (Water Overlay)]]
*[[Terrain water manning (Water Overlay)]]
* [[Manning prequel (Water Overlay)]]
|references=
<references>
<ref name="WikiEngineer">WikiEngineer (2008-2011). Manning Roughness Coefficients. Retrieved from: http://wikiengineer.com/Water-Resources/ManningRoughnessCoefficients </ref>
</references>
}}


{{WaterOverlay_hydrological_construction_attribute_nav}}
{{WaterOverlay hydrological building attribute nav}}
{{Water Module buttons}}

Latest revision as of 09:30, 27 February 2024

The default function values for a number of buildings. The user can easily change these values.

Buildings have an inherent "roughness", affecting the flow of water across their surface, which is expressed by the Gauckler–Manning coefficient or, in short, Manning's value (n).

Notes

  • The manning value can alternatively be provided as a prequel.
  • The default function values are derived from online accessible databases[1] and are readily adjustable by the user.
  • If no Buildings are present on a Terrain, the WATER_MANNING value of the surface terrain is used.

See also

References

  1. WikiEngineer (2008-2011). Manning Roughness Coefficients. Retrieved from: http://wikiengineer.com/Water-Resources/ManningRoughnessCoefficients