Water manning (Water Overlay): Difference between revisions

From Tygron Preview Support Wiki
Jump to navigation Jump to search
mNo edit summary
No edit summary
 
(8 intermediate revisions by 2 users not shown)
Line 1: Line 1:
[[File:Manning_value.png|thumb|200px|right|The default function values for a number of constructions. The user can easily change these values.]]
[[File:Manning_value.png|thumb|200px|right|The default function values for a number of buildings. The user can easily change these values.]]
{{construction attributes
{{Building attributes
| <onlyinclude>
| <onlyinclude>
{{construction attributes|type=row|group=Water Overlay
{{Building attributes|type=row|group=Water Overlay
  |attribute=WATER_MANNING
  |attribute=WATER_MANNING
  |unit=s/(m<sup>1/3</sup>)
  |unit=s/(m<sup>1/3</sup>)
  |functionvalue=Manning Value
  |functionvalue=Manning Value
  |description=The Gauckler–Manning coefficient of the construction.
  |description=The Gauckler–Manning coefficient of the building.
  |icon=waterwizard_icon_manning.png
  |icon=waterwizard_icon_manning.png
|range=0.01 to 0.255
}} </onlyinclude>
}} </onlyinclude>
}}
}}


[[Construction]]s have an inherent "roughness", affecting the flow of water across their surface, which is expressed by the Gauckler–Manning coefficient or, in short, Manning's value (''n'').
[[Building]]s have an inherent "roughness", affecting the flow of water across their surface, which is expressed by the Gauckler–Manning coefficient or, in short, Manning's value (''n'').
{{clear}}
{{clear}}
{{article end
{{article end
|notes=
|notes=
* The [[Water manning prequel (Water Overlay)|manning value]] can alternatively be provided as a [[prequel]].
* The [[Manning prequel (Water Overlay)|manning value]] can alternatively be provided as a [[prequel]].
* The default function values are derived from online accessible databases<ref name="WikiEngineer"/> and are readily adjustable by the user.
* The default function values are derived from online accessible databases<ref name="WikiEngineer"/> and are readily adjustable by the user.
* If no constructions are present on a [[Terrain]], the [[Terrain water manning (Water Overlay)|WATER_MANNING]] value of the surface terrain is used.
* If no Buildings are present on a [[Terrain]], the [[Terrain water manning (Water Overlay)|WATER_MANNING]] value of the surface terrain is used.
|seealso=
|seealso=
* [[Surface flow formula (Water Overlay)]]
* [[Surface flow formula (Water Overlay)]]
* [[Surface model (Water Overlay)]]
* [[Surface model (Water Overlay)]]
*[[Terrain water manning (Water Overlay)]]
* [[Manning prequel (Water Overlay)]]
|references=
|references=
<references>
<references>
Line 27: Line 30:
}}
}}


{{WaterOverlay hydrological construction attribute nav}}
{{WaterOverlay hydrological building attribute nav}}

Latest revision as of 09:30, 27 February 2024

The default function values for a number of buildings. The user can easily change these values.

Buildings have an inherent "roughness", affecting the flow of water across their surface, which is expressed by the Gauckler–Manning coefficient or, in short, Manning's value (n).

Notes

  • The manning value can alternatively be provided as a prequel.
  • The default function values are derived from online accessible databases[1] and are readily adjustable by the user.
  • If no Buildings are present on a Terrain, the WATER_MANNING value of the surface terrain is used.

See also

References

  1. WikiEngineer (2008-2011). Manning Roughness Coefficients. Retrieved from: http://wikiengineer.com/Water-Resources/ManningRoughnessCoefficients