Ground infiltration formula (Water Overlay): Difference between revisions

From Tygron Preview Support Wiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(One intermediate revision by the same user not shown)
Line 20: Line 20:
: <math>\Delta w_u</math> = The amount of water in the unsaturated zone. The height of the water column if the equivalent amount of water was placed on the surface.
: <math>\Delta w_u</math> = The amount of water in the unsaturated zone. The height of the water column if the equivalent amount of water was placed on the surface.
: <math>r</math> = Ratio of water to height in the unsaturated zone.
: <math>r</math> = Ratio of water to height in the unsaturated zone.
: <math>\Delta t</math> = Computational timestep.
: <math>\Delta t</math> = Computational [[Timestep formula (Water Overlay)|timestep]] in seconds.
: <math>f_{i,t}</math> = The interpolated infiltration factor at time <math>t</math>. Configured using [[Infiltration_factor_s_(Water_Overlay)|INFILTRATION_FACTOR_S]].
: <math>f_{i,t}</math> = The interpolated infiltration factor at time <math>t</math>. Configured using [[Infiltration_factor_s_(Water_Overlay)|INFILTRATION_FACTOR_S]].
: <math>I_{g}</math> = The [[Terrain ground infiltration md (Water Overlay)|GROUND_INFILTRATION_MD]] of the underground terrain type.
: <math>I_{g}</math> = The [[Terrain ground infiltration md (Water Overlay)|GROUND_INFILTRATION_MD]] of the underground terrain type.

Latest revision as of 13:49, 5 March 2024

Water can infiltrate from the unsaturated zone to the saturated zone.

The infiltration from the unsaturated zone to the saturated zone is calculated per cell.

First the height of the unsaturated zone is calculated.

Then the ratio of water amount to unsaturated height is calculated.

Then we calculate the distance of the unsaturated zone which can infiltrate.

Finally, we calculate the actual amount of water that infiltrates from the unsaturated zone to the saturated zone.

Where:

= The groundwater level, relative to datum.
= the datum height of the surface of cell c, set by the elevation or a Terrain elevation prequel.
= The height of the unsaturated zone.
= The amount of water in the unsaturated zone. The height of the water column if the equivalent amount of water was placed on the surface.
= Ratio of water to height in the unsaturated zone.
= Computational timestep in seconds.
= The interpolated infiltration factor at time . Configured using INFILTRATION_FACTOR_S.
= The GROUND_INFILTRATION_MD of the underground terrain type.
= The height distance in the unsaturated zone which can be subject to infiltration to the saturated zone.
= The infiltration which takes place from the unsaturated zone to the saturated zone.

Related

The following topics are related to this formula.

Formulas
Groundwater level formula (Water Overlay)
Surface infiltration formula (Water Overlay)
Ground bottom flow formula (Water Overlay)
Models
Ground model (Water Overlay)
Infiltration model (Water Overlay)
Tracer flow model (Water Overlay)