Water manning (Water Overlay): Difference between revisions
Jump to navigation
Jump to search
mNo edit summary |
No edit summary |
||
| (23 intermediate revisions by 5 users not shown) | |||
| Line 1: | Line 1: | ||
{{Overlay | [[File:Manning_value.png|thumb|200px|right|The default function values for a number of buildings. The user can easily change these values.]] | ||
|attribute=WATER_MANNING | {{Building attributes | ||
|unit=s/(m<sup>1/3</sup>) | | <onlyinclude> | ||
|functionvalue=Manning Value | {{Building attributes|type=row|group=Water Overlay | ||
|description=The Gauckler–Manning coefficient of the | |attribute=WATER_MANNING | ||
|icon= | |unit=s/(m<sup>1/3</sup>) | ||
|functionvalue=Manning Value | |||
|description=The Gauckler–Manning coefficient of the building. | |||
|icon=waterwizard_icon_manning.png | |||
|range=0.01 to 0.255 | |||
}} </onlyinclude> | |||
}} | }} | ||
= | [[Building]]s have an inherent "roughness", affecting the flow of water across their surface, which is expressed by the Gauckler–Manning coefficient or, in short, Manning's value (''n''). | ||
* If no | {{clear}} | ||
{{article end | |||
== | |notes= | ||
* The [[Manning prequel (Water Overlay)|manning value]] can alternatively be provided as a [[prequel]]. | |||
* The default function values are derived from online accessible databases{{ref|WikiEngineer}} and are readily adjustable by the user. | |||
* If no Buildings are present on a [[Terrain]], the [[Terrain water manning (Water Overlay)|WATER_MANNING]] value of the surface terrain is used. | |||
|seealso= | |||
* [[Surface flow formula (Water Overlay)]] | |||
* [[Surface model (Water Overlay)]] | |||
*[[Terrain water manning (Water Overlay)]] | |||
* [[Manning prequel (Water Overlay)]] | |||
|references= | |||
<references> | |||
{{ref|WikiEngineer | |||
|name=Manning Roughness Coefficients | |||
|author= | |||
|page= | |||
|source=WikiEngineer (2008-2011) | |||
|link=http://wikiengineer.com/Water-Resources/ManningRoughnessCoefficients | |||
|lastvisit= | |||
}} | |||
</references> | |||
}} | |||
{{ | {{WaterOverlay hydrological building attribute nav}} | ||
Latest revision as of 11:32, 17 October 2025

| Icon | Attribute | Unit | Range | Description |
|---|---|---|---|---|
| |
WATER_MANNING | s/(m1/3) | 0.01 to 0.255 | The Gauckler–Manning coefficient of the building. |
Buildings have an inherent "roughness", affecting the flow of water across their surface, which is expressed by the Gauckler–Manning coefficient or, in short, Manning's value (n).
Notes
- The manning value can alternatively be provided as a prequel.
- The default function values are derived from online accessible databases[1] and are readily adjustable by the user.
- If no Buildings are present on a Terrain, the WATER_MANNING value of the surface terrain is used.
See also
- Surface flow formula (Water Overlay)
- Surface model (Water Overlay)
- Terrain water manning (Water Overlay)
- Manning prequel (Water Overlay)
References
- ↑ Manning Roughness Coefficients ∙ WikiEngineer (2008-2011) ∙ Found at: http://wikiengineer.com/Water-Resources/ManningRoughnessCoefficients