Water manning (Water Overlay): Difference between revisions

From Tygron Preview Support Wiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(11 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{Overlay attribute
[[File:Manning_value.png|thumb|200px|right|The default function values for a number of buildings. The user can easily change these values.]]
|attribute=WATER_MANNING
{{Building attributes
|unit=s/(m<sup>1/3</sup>)
| <onlyinclude>
|functionvalue=Manning Value
{{Building attributes|type=row|group=Water Overlay
|description=The Gauckler–Manning coefficient of the construction.
|attribute=WATER_MANNING
|icon=[[File:waterwizard_icon_manning.png]]}}
|unit=s/(m<sup>1/3</sup>)
__NOTOC__
|functionvalue=Manning Value
====Manning's ''n'' (construction)====
|description=The Gauckler–Manning coefficient of the building.
[[Construction]]s have an inherent "roughness", affecting the flow of water across their surface, which is expressed by the Gauckler–Manning coefficient or, in short, Manning's value (''n'').
|icon=waterwizard_icon_manning.png
|range=0.01 to 0.255
}} </onlyinclude>
}}


====Notes====
[[Building]]s have an inherent "roughness", affecting the flow of water across their surface, which is expressed by the Gauckler–Manning coefficient or, in short, Manning's value (''n'').
{{clear}}
{{article end
|notes=
* The [[Manning prequel (Water Overlay)|manning value]] can alternatively be provided as a [[prequel]].
* The default function values are derived from online accessible databases<ref name="WikiEngineer"/> and are readily adjustable by the user.
* The default function values are derived from online accessible databases<ref name="WikiEngineer"/> and are readily adjustable by the user.
* If no constructions are present on a [[Terrain|terrain]], the [[Terrain water manning (Water Overlay)|WATER_MANNING]] value of the surface terrain is used.
* If no Buildings are present on a [[Terrain]], the [[Terrain water manning (Water Overlay)|WATER_MANNING]] value of the surface terrain is used.
[[File:Manning_value.png|thumb|200|none|alt=Alt text|The default function values for a number of constructions. The user can easily change these values.]]
|seealso=
 
* [[Surface flow formula (Water Overlay)]]
====See also====
* [[Surface model (Water Overlay)]]
* [[Surface flow formula (Water Overlay)|Surface flow formula]]
*[[Terrain water manning (Water Overlay)]]
* [[Surface model (Water_Overlay)|Surface model]]
* [[Manning prequel (Water Overlay)]]
 
|references=
==References==
<references>
<references>
<ref name="WikiEngineer">WikiEngineer (2008-2011). Manning Roughness Coefficients. Retrieved from: http://wikiengineer.com/Water-Resources/ManningRoughnessCoefficients </ref>
<ref name="WikiEngineer">WikiEngineer (2008-2011). Manning Roughness Coefficients. Retrieved from: http://wikiengineer.com/Water-Resources/ManningRoughnessCoefficients </ref>
</references>
</references>
{{WaterOverlay hydrological construction attribute nav}}
}}
 
{{WaterOverlay hydrological building attribute nav}}

Latest revision as of 09:30, 27 February 2024

The default function values for a number of buildings. The user can easily change these values.

Buildings have an inherent "roughness", affecting the flow of water across their surface, which is expressed by the Gauckler–Manning coefficient or, in short, Manning's value (n).

Notes

  • The manning value can alternatively be provided as a prequel.
  • The default function values are derived from online accessible databases[1] and are readily adjustable by the user.
  • If no Buildings are present on a Terrain, the WATER_MANNING value of the surface terrain is used.

See also

References

  1. WikiEngineer (2008-2011). Manning Roughness Coefficients. Retrieved from: http://wikiengineer.com/Water-Resources/ManningRoughnessCoefficients