Unsaturated fraction prequel (Water Overlay): Difference between revisions

From Tygron Preview Support Wiki
Jump to navigation Jump to search
No edit summary
mNo edit summary
 
(3 intermediate revisions by the same user not shown)
Line 1: Line 1:
{{Overlay prequels|overlay=Water|suppresscategory=true|allowselflinks=true|
{{Overlay prequels|overlay=Water|allowselflinks=true|
<onlyinclude>{{Overlay prequels|type=row|overlay=Water
<onlyinclude>{{Overlay prequels|type=row|overlay=Water
   |prequel=UNSATURATED_FRACTION
   |prequel=UNSATURATED_FRACTION
Line 6: Line 6:
   |min=0
   |min=0
   |max=1
   |max=1
  |defaultvalue=
}}</onlyinclude>}}
}}
</onlyinclude>}}


{{article end
{{article end
|notes=
|notes=
* The values in this prequel grid are clamped between 0 and 1. No data values are not allowed, but negative values are interpreted as zero saturation.
* The values in this prequel grid are clamped between 0 and 1. No data values are not allowed, but negative values are interpreted as zero saturation.
* Note that this fraction is relative to the maximum water storage capacity of the terrain and not relative to the underground terrain volume. This amounts to the following formula: <br>Amount of water in the unsaturated zone = relative ground water depth * [[Terrain water storage percentage (Water Overlay)|WATER_STORAGE_PERCENTAGE]] * [[Unsaturated fraction (Water Overlay)|UNSATURATED_FRACTION]].
* For example, an underground terrain with a water storage of 25% and a ground water depth of 1 m and a configured unsaturated fraction of 0.25 will result in 0.0625 meter water in the unsaturated zone. (25% of 25% of the total volume of 1 m3)
|seealso=
|seealso=
* [[Unsaturated fraction (Water Overlay)]]
* [[Unsaturated fraction (Water Overlay)]]

Latest revision as of 14:58, 3 June 2022


Notes

  • The values in this prequel grid are clamped between 0 and 1. No data values are not allowed, but negative values are interpreted as zero saturation.
  • Note that this fraction is relative to the maximum water storage capacity of the terrain and not relative to the underground terrain volume. This amounts to the following formula:
    Amount of water in the unsaturated zone = relative ground water depth * WATER_STORAGE_PERCENTAGE * UNSATURATED_FRACTION.
  • For example, an underground terrain with a water storage of 25% and a ground water depth of 1 m and a configured unsaturated fraction of 0.25 will result in 0.0625 meter water in the unsaturated zone. (25% of 25% of the total volume of 1 m3)

See also