Unsaturated fraction prequel (Water Overlay): Difference between revisions

From Tygron Preview Support Wiki
Jump to navigation Jump to search
mNo edit summary
No edit summary
Line 1: Line 1:
{{Overlay prequels|overlay=Water|suppresscategory=true|allowselflinks=true|
{{Overlay prequels|overlay=Water|allowselflinks=true|
<onlyinclude>{{Overlay prequels|type=row|overlay=Water
<onlyinclude>{{Overlay prequels|type=row|overlay=Water
   |prequel=UNSATURATED_FRACTION
   |prequel=UNSATURATED_FRACTION

Revision as of 15:08, 3 March 2022


Notes

  • The values in this prequel grid are clamped between 0 and 1. No data values are not allowed, but negative values are interpreted as zero saturation.
  • Note that this fraction is relative to the maximum water storage capacity of the terrain and not relative to the underground terrain volume. This amounts to the following formula:
    Amount of water in the unsaturated zone = relative ground water depth * WATER_STORAGE_PERCENTAGE * UNSATURATED_FRACTION.
  • For example, an underground terrain with a water storage of 25% and a ground water depth of 1 m and a configured unsaturated fraction of 0.25 will result in 0.0625 meter water in the unsaturated zone. (25% of 25% of the total volume of 1 m3)

See also