Ground bottom flow formula (Water Overlay): Difference between revisions
Jump to navigation
Jump to search
mNo edit summary |
mNo edit summary |
||
Line 15: | Line 15: | ||
* <math>h_{x,y}</math> = [[Groundwater level formula (Water Overlay)|Ground water head]] in the grid cell. | * <math>h_{x,y}</math> = [[Groundwater level formula (Water Overlay)|Ground water head]] in the grid cell. | ||
* <math>h_{d}(t)</math> = Additional ground water level (or head) of the external zone causing the seepage at time t, in meters | * <math>h_{d}(t)</math> = Additional ground water level (or head) of the external zone causing the seepage at time t, in meters | ||
* <math>h_{c_{x,y}}</math> = Constant ground water level (or head) of the external zone causing the seepage, in meters | * <math>h_{c_{x,y}}</math> = [[Seepage GeoTiffs (Water Overlay)#Seepage p|Constant ground water level (or head) of the external zone]] causing the seepage, in meters | ||
* <math>h_{v}(t)</math> = Additional variation of seepage head over time | * <math>h_{v}(t)</math> = [[Seepage fluctuation (Water Overlay)|Additional variation of seepage head]] over time | ||
* <math>c_{x,y}</math> = Resistance of the separating layer in days | * <math>c_{x,y}</math> = [[Seepage GeoTiffs (Water Overlay)#Seepage c|Resistance of the separating layer]] in days | ||
* <math>ws</math> = Water storage fraction of the soil | * <math>ws</math> = [[Terrain water storage percentage (Water Overlay)|Water storage fraction]] of the soil | ||
* <math>\Delta w_{x,y}</math> = Seeped in water in m | * <math>\Delta w_{x,y}</math> = Seeped in water in m | ||
Revision as of 11:53, 2 September 2020
Underground seepage from outside the project area is calculated per grid cell.
The water level change due to seepage is calculated using the following formula:
The external seepage head is variable over time by the introduction of hv,t:
Finally, the actual amount of water seeping into the ground from the bottom is calculated as followed:
Where:
- = The water level change due to seepage, in meters.
- = Computational timestep in seconds.
- = Ground water head in the grid cell.
- = Additional ground water level (or head) of the external zone causing the seepage at time t, in meters
- = Constant ground water level (or head) of the external zone causing the seepage, in meters
- = Additional variation of seepage head over time
- = Resistance of the separating layer in days
- = Water storage fraction of the soil
- = Seeped in water in m
Notes
- and can both be provided as spatially variable values.
- can be provided as a set of values, variable over time.
- A seepage head lower than the water level in the project is also allowed, resulting in water seeping out to a region outside the project area.
See also
- The formula is based on the formula of Pankow for estimating seepage
- Seepage result
- Seepage geotiffs
- Seepage fluctuation