Groundwater level formula (Water Overlay): Difference between revisions
Jump to navigation
Jump to search
mNo edit summary |
mNo edit summary |
||
Line 22: | Line 22: | ||
: [[Surface infiltration formula (Water Overlay)|Surface infiltration formula]] | : [[Surface infiltration formula (Water Overlay)|Surface infiltration formula]] | ||
: [[Underground infiltration formula (Water Overlay)|Underground infiltration formula]] | : [[Underground infiltration formula (Water Overlay)|Underground infiltration formula]] | ||
: [[Underground seepage formula (Water Overlay)|Underground seepage formula]] | |||
; Models | ; Models | ||
: [[Surface model (Water Overlay)|Surface model]] | : [[Surface model (Water Overlay)|Surface model]] |
Revision as of 13:22, 2 September 2020
Groundwater level is calculated per cell.
Where:
- = The height (column) of the saturated zone.
- = The amount of water in the saturated zone. The height of the water column if the equivalent amount of water was placed on the surface.
- = The WATER_STORAGE_PERCENTAGE of the underground terrain type, used here as a fraction.
- = The groundwater level, relative to datum. Also known as the watertable.
- = The surface height in the cell, relative to datum.
- = The GROUND_BOTTOM_DISTANCE_M (effectively available height in the underground model).
Related
The following topics are related to this formula.