Drainage passive
First the flow capacity is calculated
if then:
else:
Drainage active
Case 1: Active Draining:
If a positive Pump q is defined:
If a lower threshold Tl,t is defined as well:
If an upper threshold T_{u,t} is defined as well:
If a capacity Qtotal is defined:
After calculating the capacities, the actual water pumped upwards is calculated. If any of the terms are undefined, they are not included.
Case 2: Active Reverse Draining:
If a negative Pump q is defined:
If a lower threshold Tl,t is defined as well:
If an upper threshold Tu,t is defined as well:
If a capacity Qtotal is defined:
After calculating the capacities, the actual water pumped upwards is calculated. If any of the terms are undefined, they are not included.
Where:
- is the ground water level in meters
- is the water level in the waterway
- is the drainage datum height in meters.
- is the drainage area size in square meters.
- is the waterway area size in square meters.
- is the max waterway height.
- is the average storage percentage of the ground above the drainage.
- is the amount transferred for a balanced ground and surface water level
- is the amount available in the ground above the drainage.
- is the drainage capacity at time t
- is the actual drained volume at time t
Related
The following topics are related to this formula.
- Structures
- Drainage
- Models
- Surface model
- Underground model