Flow through breaches is calculated based on the weir formula, including the consideration between free flow and submerged flow situations. The weir formula is supplied with the breach width (as stand-in for the weir width), which is always calculated with the breach growth formula before calculating the weir flow. The downstream water level can optionally be measured with an additionally configured Breach Level Area, or an automatically placed

For the entry area, the area where the water originates from, the following also applies:

Each timestep, the external water level is changed based on the amount of water flowing in or out.

Where:

= The calculated water flow which takes place, based on the weir formula.
= The water level of the entry area at time ; In case of an external area: EXTERNAL_WATER_LEVEL of the breach.
Failed to parse (Conversion error. Server ("https://wikimedia.org/api/rest_") reported: "Cannot get mml. upstream connect error or disconnect/reset before headers. reset reason: connection termination"): {\displaystyle A_{e}_{s}} = The size of in the entry area; In case of an external area: EXTERNAL_AREA of the breach.
Failed to parse (Conversion error. Server ("https://wikimedia.org/api/rest_") reported: "Cannot get mml. TeX parse error: Double subscripts: use braces to clarify"): {\displaystyle A_{e}_{b}} = The (optional) size of the bottom of the entry area; In case of an external area: the second value provided for the EXTERNAL_AREA of the breach.

Notes

  • The water level we cannot become lower than the surface height se, defined by EXTERNAL_SURFACE_LEVEL in case of an external entry area. In case of an input area within the project, the surface height is determined per grid cell.

Related

The following topics are related to this formula.

Features
Breach
Formulas
Weir formula
Breach growth formula
Models