Breach flow formula (Water Overlay)

From Tygron Preview Support Wiki
Jump to navigation Jump to search

Flow through breaches is calculated based on the weir formula, including the consideration between free flow and submerged flow situations. The weir formula is supplied with the breach width (as stand-in for the weir width), which is always calculated with the breach growth formula before calculating the weir flow. The downstream water level can optionally be measured with an additionally configured Breach Level Area, or an automatically placed

For the entry area, the area where the water originates from, the following also applies:

Each timestep, the external water level is changed based on the amount of water flowing in or out.

Where:

= The calculated water flow which takes place, based on the weir formula.
= The water level of the entry area at time ; In case of an external area: EXTERNAL_WATER_LEVEL of the breach.
= The size of in the entry area; In case of an external area: EXTERNAL_AREA of the breach.
= The (optional) size of the bottom of the entry area; In case of an external area: the second value provided for the EXTERNAL_AREA of the breach. In case only one value is provided,

Notes

  • The water level we cannot become lower than the surface height se, defined by EXTERNAL_SURFACE_LEVEL in case of an external entry area. In case of an input area within the project, the surface height is determined per grid cell.

Related

The following topics are related to this formula.

Features
Breach
Formulas
Weir formula
Breach growth formula
Models
Surface model