Sewer area (Water Overlay): Difference between revisions

From Tygron Preview Support Wiki
Jump to navigation Jump to search
No edit summary
mNo edit summary
Line 1: Line 1:
A sewer area is part of the definition of a [[sewer model (Water Overlay)|system of sewers]] in the specified area. A sewer is assumed to be present in all locations where a sewer area intersects with a [[Sewered_(Water_Overlay)| sewered construction]].
A sewer area is part of the definition of a [[sewer model (Water Overlay)|system of sewers]] in the specified area. A sewer is assumed to be present in all locations where a sewer area intersects with a [[Sewered (Water Overlay)| sewered construction]].


In other words, a sewer is present if:
In other words, a sewer is present if:
* It is covered by a construction with a [[Sewered_(Water_Overlay)|SEWERED]] attribute > 0.
* It is covered by a construction with a [[Sewered (Water Overlay)|SEWERED]] attribute > 0.
* It is covered by a sewer area with a [[Sewer_storage_(Water_Overlay)|SEWER_STORAGE]] attribute > 0.
* It is covered by a sewer area with a [[Sewer storage (Water Overlay)|SEWER_STORAGE]] attribute > 0.


A sewer area can also pump stored sewer water to an [[External area (Water Overlay)|external area]] outside the project. However, water that has been pumped out will remain in the external area and cannot be pumped back. By default sewers do not pump water to external areas.
A sewer area can also pump stored sewer water to an [[External area (Water Overlay)|external area]] outside the project. However, water that has been pumped out will remain in the external area and cannot be pumped back. By default sewers do not pump water to external areas.
{{Overlay keys|suppresscategory=true|
{{Overlay keys|suppresscategory=true|
{{:Sewer storage (Water Overlay)}}
{{:Sewer storage (Water Overlay)}}

Revision as of 09:08, 8 October 2020

A sewer area is part of the definition of a system of sewers in the specified area. A sewer is assumed to be present in all locations where a sewer area intersects with a sewered construction.

In other words, a sewer is present if:

  • It is covered by a construction with a SEWERED attribute > 0.
  • It is covered by a sewer area with a SEWER_STORAGE attribute > 0.

A sewer area can also pump stored sewer water to an external area outside the project. However, water that has been pumped out will remain in the external area and cannot be pumped back. By default sewers do not pump water to external areas.

Notes

How-to's

See also