{{Overlay prequel|overlay=Water|suppresscategory=true|allowselflinks=true|
{{Overlay prequels|overlay=Water|
{{Overlay prequel|overlay=Water|type=row|prequel=TERRAIN_ELEVATION|name=Terrain elevation prequel|description=Used for initializing the terrain elevation on this datum.}}
<onlyinclude>{{Overlay prequels|type=row|overlay=Water
}}
|prequel=TERRAIN_ELEVATION
|name=Terrain elevation
|description=Used for initializing the terrain elevation on this datum.
|min=-10000
|max=10000
|unit=m {{datum}}
}}</onlyinclude>}}
 
This prequel serves as a replacement for the DTM, which is the elevation model without the [[Building]]s. The [[Water Overlay]] will still add the heights of any [[Building]]s present, in accordance with the set [[design flood elevation m (Water Overlay)|DESIGN_FLOOD_ELEVATION M]].
 


{{article end
{{article end
|notes=* The values in this prequel grid are clamped between -10000.0 and 10000.0. No data values are not allowed.
|notes=* '''IMPORTANT''': This prequel Overlay must be set to [[How to set an Overlay to active or inactive|inactive]] in order to function properly!
* The values in this prequel grid are clamped between -10000.0 and 10000.0. No data values are not allowed.
* Any [[Grid Overlay]] used as input for this [[prequel]] should cover the [[project area]] completely, without any {{nodata}} values. If the dataset used does contain {{nodata}} values, it is prudent to use a [[Combo Overlay]] or an [[Average Overlay]] to fill up any {{nodata}} values, and use that [[Grid Overlay]] as input for this [[prequel]] instead.
|seealso=
* [[Elevation model (Water Overlay)]]
* [[Elevation (Water Overlay)]]
* [[Prequel]]
}}
}}


{{WaterOverlay simulation data nav}}
{{WaterOverlay simulation data nav}}

Latest revision as of 16:48, 5 March 2024


This prequel serves as a replacement for the DTM, which is the elevation model without the Buildings. The Water Overlay will still add the heights of any Buildings present, in accordance with the set DESIGN_FLOOD_ELEVATION M.


Notes

  • IMPORTANT: This prequel Overlay must be set to inactive in order to function properly!
  • The values in this prequel grid are clamped between -10000.0 and 10000.0. No data values are not allowed.
  • Any Grid Overlay used as input for this prequel should cover the project area completely, without any NO_DATA values. If the dataset used does contain NO_DATA values, it is prudent to use a Combo Overlay or an Average Overlay to fill up any NO_DATA values, and use that Grid Overlay as input for this prequel instead.

See also