(Created page with "Besides the buildings which directly influence the hydrologic model as a hydraulic structure, each construction may also have attributes which can contribute to the hydrological model in some way. These attributes are stored and used on a grid cell level. This is different from the hydraulic structure attributes, which are stored and used on an object level. These attributes can be changed individually per construction or pe...") |
No edit summary |
||
(3 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
Besides the [[building]]s which directly influence the hydrologic model as a [[Hydraulic structures (Water Overlay)|hydraulic structure]], each | Besides the [[building]]s which directly influence the hydrologic model as a [[Hydraulic structures (Water Overlay)|hydraulic structure]], each Building may also have attributes which can contribute to the hydrological model in some way. These attributes are stored and used on a grid cell level. This is different from the hydraulic structure attributes, which are stored and used on an object level. | ||
These attributes can be changed individually per | These attributes can be changed individually per Building or per building's function. In most cases, these attributes already exist as a [[function values|function value]]. | ||
{{building attributes|suppresscategory=true|allowselflinks=true| | {{building attributes|suppresscategory=true|allowselflinks=true| | ||
{{:Building height (Water Overlay)}} | |||
{{:Critical infrastructure (Water Overlay)}} | |||
{{:Ground infiltration md (Water Overlay)}} | {{:Ground infiltration md (Water Overlay)}} | ||
{{:Root depth m (Water Overlay)}} | |||
{{:Sewered (Water Overlay)}} | {{:Sewered (Water Overlay)}} | ||
{{: | {{:Solid (Water Overlay)}} | ||
{{:Water evaporation factor (Water Overlay)}} | {{:Water evaporation factor (Water Overlay)}} | ||
{{:Water manning (Water Overlay)}} | {{:Water manning (Water Overlay)}} | ||
{{:Water microrelief m (Water Overlay)}} | |||
{{:Water storage m2 (Water Overlay)}} | |||
{{:Tracer ABCD (Water Overlay)}} | {{:Tracer ABCD (Water Overlay)}} | ||
}} | }} | ||
Line 23: | Line 25: | ||
}} | }} | ||
{{WaterOverlay hydrological | {{WaterOverlay hydrological building attribute nav}} | ||
[[Category:Water Module]] | [[Category:Water Module]] |
Latest revision as of 13:26, 12 October 2023
Besides the buildings which directly influence the hydrologic model as a hydraulic structure, each Building may also have attributes which can contribute to the hydrological model in some way. These attributes are stored and used on a grid cell level. This is different from the hydraulic structure attributes, which are stored and used on an object level.
These attributes can be changed individually per Building or per building's function. In most cases, these attributes already exist as a function value.
Icon | Attribute | Unit | Range | Description |
---|---|---|---|---|
FLOOR_HEIGHT_M | m | The height of a floor in a building. Additionally each section of a building can have a different amount of floors. | ||
CRITICAL_INFRASTRUCTURE | nominal | Whether this building is deemed a critical. 0 means the building is never deemed impacted. | ||
GROUND_INFILTRATION_MD | m/day | The speed at which water can flow vertically from the surface to the unsaturated zone. | ||
ROOT_DEPTH_M | m | 0 to 65519 | The depth of the roots of this Building, relative to the terrain height at the location of this Building. Water can be drawn from the ground and evaporated if the roots can reach it. | |
SEWERED | boolean | Whether this building is connected to the sewer. | ||
SOLID | boolean | Whether the building is solid and blocks water flow or not. | ||
WATER_EVAPORATION_FACTOR | factor | 0 to 65519 | Factor indicating how much a building with a crop, tree or plant function facilitates evapotranspiration. This factor is multiplied with the weather's evaporation rate at a particular time in the simulation. | |
WATER_MANNING | s/(m1/3) | 0.01 to 0.255 | The Gauckler–Manning coefficient of the building. | |
WATER_MICRORELIEF_M | m | 0 - 0.255 | The height and depth of microrelief hills, in which water can be stored. | |
WATER_STORAGE | m³/m² | The amount of water this building can store. | ||
TRACER_A | x/m²/s | -3.4028235E38 to 3.4028235E38 | The amount of tracer A created per second per m² in this location. | |
TRACER_B | x/m²/s | -3.4028235E38 to 3.4028235E38 | The amount of tracer B created per second per m² in this location. | |
TRACER_C | x/m²/s | -3.4028235E38 to 3.4028235E38 | The amount of tracer C created per second per m² in this location. | |
TRACER_D | x/m²/s | -3.4028235E38 to 3.4028235E38 | The amount of tracer D created per second per m² in this location. |
In addition to the Attributes of Buildings affecting the calculations of the Water Overlay, the building height of Buildings affects the interpretation of the elevation model.
Notes
- In contrast with hydraulic structures, which can only behave as a single hydraulic object, buildings can have all of the above effects on the hydrological model simultaneously.
- Attributes which are connected to a function value can not be redefined using a different attribute name.