Search results

Jump to navigation Jump to search
  • {{Overlay attributes|<onlyinclude> {{Overlay attributes|type=row|overlay=Water
    1 KB (178 words) - 14:58, 6 February 2023
  • {{result types|type=row|overlay=Water |mode=[[Result type (Water Overlay)#Last_resulttype|Last]]
    479 bytes (70 words) - 10:34, 11 February 2022
  • {{result types|type=row|overlay=Water |mode=[[Result type (Water Overlay)#Last_resulttype|Last]]
    479 bytes (70 words) - 10:34, 11 February 2022
  • {{result types|type=row|overlay=Water |mode=[[Result type (Water Overlay)#Last_resulttype|Last]]
    479 bytes (70 words) - 10:34, 11 February 2022
  • {{result types|type=row|overlay=Water |mode=[[Result type (Water Overlay)#Last_resulttype|Last]]
    479 bytes (70 words) - 10:34, 11 February 2022
  • ...a [[Water Overlay]] wizard when the [[Ground water (Water Overlay)|Ground water mode]] is set to '''Complete'''.]] {{Overlay attributes|<onlyinclude>
    1 KB (178 words) - 14:44, 5 March 2024
  • ...mpact on the results. Drainages can be modeled using the [[Drainage (Water Overlay)|drainage]] [[Building]], and can be configured as either active drainages | Add a new underground [[Building]] to the Project.
    2 KB (343 words) - 15:48, 30 January 2024
  • ...ll as for calculation models ranging from the Average Overlay to the Water Overlay. ...D Visualization]]. [[Water (Terrain Attribute)|Water]] is most obvious, as water will be drawn on top of the existing [[Terrain]]. However, all Terrain Type
    3 KB (475 words) - 16:44, 27 February 2024
  • [[File:underground_model.jpg|thumb|right|Water can infiltrate from the unsaturated zone to the saturated zone.]] Then the ratio of water amount to unsaturated height is calculated.
    2 KB (358 words) - 13:49, 5 March 2024
  • ...rains will be present: one [[layer|surface layer]] Terrain and one [[layer|underground]] Terrain. {{main|Elevation model}}
    2 KB (302 words) - 14:32, 29 February 2024
  • ...ater at a defined maximum rate, with optional thresholds for the amount of water to add or remove. {{Overlay keys|suppresscategory=true|
    2 KB (309 words) - 09:41, 29 January 2024
  • '''Water''' * New Watershed Overlay.
    742 bytes (93 words) - 15:57, 3 March 2021
  • ...y for their computed groundwater levels, it's possible to set up a dynamic model in which actions can directly influence the viability of crops, and thus th ...or subsidence, and its effects on groundwater when using the [[Waterwijzer Overlay]], make sure:
    3 KB (442 words) - 13:35, 30 January 2024
  • ...in the {{software}} is an implementation of a 2D grid based shallow water model based on the 2D Saint Venant equations. The module is further enhanced with ...cell communicates with its adjacent cells to exchange water, based on its water level, surface height, current flow direction and other factors. Accuracy a
    6 KB (918 words) - 13:40, 17 January 2023
  • [[File:Api_current_situation_calculation.png|thumb|right|400px|[[Overlay]] in comparison to [[Measurement]]s, [[Indicator]]s and [[Global]]s]] An overlay is a layer visualized on top of the [[terrain]] and [[building]]s in the 3D
    12 KB (1,575 words) - 15:33, 29 February 2024
  • [[File:Api_current_situation_geography.png|thumb|right|400px|[[Elevation model]] in relation to [[Terrain]]s, [[Height sector]]s and [[Elevation GeoTIFF]] ...cape. On a small scale, differences in terrain height can affect shade and water distribution. On a larger scale, terrain height has an effect on weather an
    10 KB (1,645 words) - 11:26, 7 November 2023
  • ...is possible to configure the parameters manually, or by using the [[Water Overlay Wizard|configuration wizard]]. A few settings can only be changed manually. {{main|Grid overlay#Shared settings|Grid overlay}}
    9 KB (1,447 words) - 15:36, 30 January 2024
  • ...e selected area. Find an overview on which data is used to create a new 3D model on the [[Project Sources]] page. ..., railway lines. Deactivating will lead to a less detailed and accurate 3D model.
    6 KB (973 words) - 16:50, 28 February 2023
  • The [[Waterwijzer_Overlay#Module|Waterwijzer Overlay]] communicates with the [https://waterwijzerlandbouw.wur.nl/query-wdb.php?f ...umber for the type of plot, which is stored in the [[Brp code (Waterwijzer Overlay)|BRP_CODE]] attribute.
    4 KB (582 words) - 14:32, 13 December 2023
  • ...sport water to, from, and between specified cells, according to their flow model and given parameters. The behavior of these Buildings can be adjusted by ad In general, for ease of use, hydraulic structures are by default imported as underground Buildings.
    6 KB (875 words) - 11:36, 5 October 2022
  • ...FF]] (if provided) and is optionally overwritten by (managed) water areas' water level. ...nage (Subsidence Overlay)|actively]] or [[Low passive_drainage (Subsidence Overlay)|passively]].
    7 KB (1,208 words) - 12:25, 17 January 2022
  • ...an be inspected after the overlay has been calculated by opening the water overlay wizard and inspecting the error feedback for the specific steps. ...e data as individual [[building]]s, or there are multiple [[culvert (Water Overlay)|culvert]] tubes parallel to one another connecting two waterways.
    9 KB (1,326 words) - 13:44, 30 January 2024
  • | demographic=hydrologists and other water experts ...lowing the [[Ground bottom flow formula (Water Overlay)|formula for ground water flow from deeper ground layers through the bottom boundary]]
    9 KB (1,475 words) - 16:19, 26 January 2024
  • ...hydrological building]]s are correctly configured, the more accurately the water flow can be simulated. ===Determine what overlay you need===
    12 KB (1,928 words) - 15:25, 23 February 2023
  • By creating a [[Project]] with controlled parameters for the [[Waterwijzer Overlay]], and comparing the results through a sample test, we have verified that t ...waterwijzer' />. Because the {{software}} connects to the same calculation model, the same input should also lead to the same output.
    11 KB (1,516 words) - 09:05, 3 October 2023
  • ...l possible warnings which may be encountered when working with the [[Water Overlay]]. When the [[Water Overlay]] is selected in the [[Editor]], a number of warnings may appear in the [[r
    43 KB (6,629 words) - 13:04, 1 March 2023
  • |additional=Knowledge of the functioning of the water module is recommended, but not required. * The surface of the terrain is the "Open Land" type. The underground terrain is the "Unknown" type.
    35 KB (5,923 words) - 14:14, 30 January 2023
  • * New Image Wizard for importing a WMS (Web Map Service) into an Overlay. * The [[Source_(Overlay)|Source Overlay]] that shows the different sources used in the project.
    17 KB (2,705 words) - 07:13, 14 June 2019
  • ...uch as [[Heat Overlay|heat]], [[Water Overlay|water]], and [[Traffic Noise Overlay|traffic effects]]. ...are map layers which can be switched between. By default, the following [[Overlay]]s are available:
    45 KB (6,912 words) - 09:25, 17 April 2024