(Created page with "{{Overlay keys|<onlyinclude> {{Overlay keys|type=row|group=Water Overlay |key=PUMP_AREA |unit={{boolean}} |description=When true the {{Pump}} is spread across the entire build...")
 
No edit summary
 
(3 intermediate revisions by one other user not shown)
Line 3: Line 3:
|key=PUMP_AREA
|key=PUMP_AREA
|unit={{boolean}}
|unit={{boolean}}
|description=When true the {{Pump}} is spread across the entire building surface.
|description=When true the [[Pump (Water Overlay)|Pump]] is spread across the entire building surface.
|defaultvalue=0
|defaultvalue=0
|icon=waterwizard_icon_pump_area.png
|icon=waterwizard_icon_pump_area.png
}}</onlyinclude>}}
}}</onlyinclude>}}


<gallery widths=300px heights=300px>
WaterOverlay_pump_points.png|A pump consisting of one line area, with one entry point for the lower and one for the upper [[Water level area (Water Overlay)|Water level area]]s. It only used a single cell to subtract water from, which might not be enough.
WaterOverlay_pump_points_basetype.png|The base type overlay indicating that only one cell is used to subtract water from.
WaterOverlay_pump_areas.png|A pump consisting of two separate areas, one for the lower and one for the upper [[Water level area (Water Overlay)|Water level area]]s. It uses a lower level threshold and requires multiple grid cells to subtract enough water. It is configured as a [[Pump area (Water Overlay)|PUMP_AREA]].
WaterOverlay_pump_areas_basetype.png|The base type overlay indicating that this pump now uses multiple cells to subtract water from.
</gallery>
{{article end
{{article end
|notes=
|notes=
* Selecting this option is useful when the [[Pump q (Water Overlay)|Pump_Q]] value is too large for a single cell.
* Selecting this option is useful when the [[Pump q (Water Overlay)|PUMP_Q]] value is too large for a single cell.
|seealso=
* This requires the pump to consist of 2 discrete polygons. This can either be as a single section with 2 seperate polygons, or as 2 seperate sections with 1 polygon each.
|troubles=
* [[Troubleshoot: Configured lower threshold for pump is not reached]]
|howtos=
|howtos=
}}
}}